According to the different nature of pharmaceutical production requirements solvents and media technology engineering titanium plate suppliers company for titanium filter regeneration procedures are as follows:
titanium bar rod sheet plate caustic: 3-5% solution of sodium hydroxide AR soak for 30-60 minutes, the temperature around 40 degrees. Best in ultrasonic cleaning machine. After soaking with deionized water or filtered water for injection and outside the red to neutral, measured conductivity. Dry with clean air ≥0.4Mpa pressure.
titanium bar rod sheet plate pickling: 5% nitric acid solution soak for more than eight hours, the temperature was 40 degrees.medical titanium plate Best in ultrasonic cleaning machine. After soaking with deionized water or filtered water for injection and outside the red to neutral, measured conductivity. Dry with clean air ≥0.4Mpa pressure.
The above two methods may be used alone may also be used interchangeably with each other. If the conditions can be combined with ultrasonic cleaning machine best.